155
Preset White
Makes settings related to
white balance preset
values.
Color Temp <P>
1500K to
3200K
to 50000K
Sets the white balance preset value.
C.Temp BAL <P>
–99 to
±0
to +99
Sets the fine color temperature settings, for use
when a satisfactory image cannot be obtained
using Color Temp <P>.
R Gain <P>
–99 to
±0
to +99
Sets the R gain preset value.
B Gain <P>
–99 to
±0
to +99
Sets the B gain preset value.
AWB Enable <P>
On/
Off
Turns execution of the AWB (auto white
balance) function on/off when the WHITE BAL
switch is set to PRST.
Color Temp <P>
1500K to
3200K
to 50000K
Sets the white balance preset value.
C.Temp BAL <P>
–99 to
±0
to +99
Sets the fine color temperature settings, for use
when a satisfactory image cannot be obtained
using Color Temp <P>.
R Gain <P>
–99 to
±0
to +99
Sets the R gain preset value.
B Gain <P>
–99 to
±0
to +99
Sets the B gain preset value.
AWB Enable <P>
On/
Off
Turns execution of the AWB (auto white
balance) function on/off when the WHITE BAL
switch is set to PRST.
White Filter
Makes settings related to
filters.
ND Filter C.Temp
On/
Off
Turns the function that assigns electrical CC
filters to ND filters on/off.
ND FLT C.Temp<1>
3200K
/4300K/5600K/
6300K
Selects the color temperature when electrical CC
filters are assigned to ND filters (filter 1).
ND FLT C.Temp<2-4>
3200K
/4300K/5600K/
6300K
Selects the color temperature when electrical CC
filters are assigned to ND filters (filters 2 to 4).
Electrical CC<A>
3200K
/4300K/5600K/
6300K
Selects the color temperature when the electrical
CC filter switching function is assigned to an
assignable switch.
Electrical CC<B>
3200K/
4300K
/5600K/
6300K
Selects the color temperature when the electrical
CC filter switching function is assigned to an
assignable switch.
Electrical CC<C>
3200K/4300K/
5600K
/
6300K/---
Selects the color temperature when the electrical
CC filter switching function is assigned to an
assignable switch. Select “----” if not using C.
Electrical CC<D>
3200K/4300K/5600K/
6300K
/---
Selects the color temperature when the electrical
CC filter switching function is assigned to an
assignable switch. Select “----” if not using D.
Maintenance
Item
Sub-item setting
Description