![Sony PXW-X500 Скачать руководство пользователя страница 78](http://html.mh-extra.com/html/sony/pxw-x500/pxw-x500_manual_1323820078.webp)
78
2
Turn the MENU knob to select [On],
then press the knob.
Slow & Quick Motion starts, and “S&Q
Stby” appears in the recording status
indicator area in the viewfinder.
Next, set the frame rate.
3
Select Operation >Rec Function >Slow
& Quick Motion >Frame Rate in the
setup menu.
4
Turn the MENU knob to select the
frame rate, then press the knob.
When you finish making these settings, the
system frequency and the frame rate appear at the
top of the viewfinder screen. You can change the
frame rate while viewing the display in the
viewfinder by turning the MENU knob.
The Slow & Quick Motion mode setting and the
frame rate are retained even after the camcorder is
powered off.
Notes
• Slow & Quick Motion cannot be used if the video
format is set to XAVC and the PXWK-503
Slow&Quick Option (available separately) is not
installed.
• Only one special recording function, such as Slow &
Quick Motion, can be used at any one time.
• If another special recording function is enabled while
using Slow & Quick Motion, Slow & Quick Motion is
automatically canceled.
• Slow & Quick Motion cannot be set during recording,
playback, or while the thumbnail screen is displayed.
• Slow & Quick Motion cannot be set if the slow shutter
function is set.
To shoot using Slow & Quick Motion
Shoot as described in
When recording starts, the “S&Q Stby”
indication in the viewfinder changes to the
“
z
S&Q Rec” indication. The TALLY indicators
and the tally indicator on the front panel of the
viewfinder light as they do during normal
recording.
To stop shooting
Stop the recording.
Note
It takes longer than normal for recording to stop when the
frame rate is set to a low value (for a slow frame rate).
To exit Slow & Quick Motion mode
With the camcorder in recording standby mode,
set Operation >Rec Function >Slow & Quick in
the setup menu to [Off].
Limitations during recording
• Regardless of the setting of the F-RUN/SET/R-
RUN switch, the advance mode of the internal
timecode generator is always R-RUN.
• Audio cannot be recorded when the recording
and playback frame rates differ.
• Reviewing the recording (Rec Review) is not
possible.
• If you change the recording frame rate to a value
faster than the current shutter speed, the shutter
speed is changed to the slowest value for which
shooting is possible.
Example:
If the frame rate is 32 and the shutter
speed is
1
/
40
, and you change the frame rate to
55, then the shutter speed is changed to
1
/
60
.
It is not possible to select a shutter speed that is
slower than the recording frame rate.
• Genlock is not possible.
Normally, a clip is created as an independent file
each time that you start and stop recording. But
this function allows you to start and stop
recording while continuously recording to the
same clip, for as long as the function remains
enabled.
This is convenient when you do not want to
generate a large number of short clips, and when
you want to record without worrying about
exceeding the clip limit.
It is still easy to find recording start points,
because a Rec Start essence mark is recorded at
the recording start point each time you start
recording.
This function is enabled when the camcorder is
set to any of the following video formats
XAVC-I
XAVC-L
MPEG HD 422
Recording with the Clip
Continuous Rec Function