![Sony PXW-X500 Скачать руководство пользователя страница 86](http://html.mh-extra.com/html/sony/pxw-x500/pxw-x500_manual_1323820086.webp)
86
To release remote control mode
Turn off the camcorder and disconnect the remote
control unit.
The switch settings on the camcorder become
enabled.
To connect a monitor to the RM-B170/
B750
The MONITOR connector (BNC type) of the
RM-B170/B750 outputs the same signal as the
output from the VIDEO OUT connector.
To connect a monitor to the MONITOR
connector on the RM-B170/B750, use the black
cable supplied with the RM-B170/B750.
Image quality adjustments when the RM-
B170/B750 is connected
When the RM-B170/B750 is connected, the
parameters for camera image quality adjustment
items (paint data) are set to the parameters that
were specified the last time that the RM-B170/
B750 was connected.
Function of the recording start/stop
buttons when the RM-B170/B750 is
connected
Set the function of the buttons using Maintenance
>Camera Config >RM Rec Start in the setup
menu.
RM Rec Start settings and button functions
Data structure of image quality
adjustment data
The non-volatile memory of the camcorder used
for storing camera image quality adjustment data
(paint data) consists of two regions as shown
below: a “main data block” that is used when a
remote control unit is not connected, and a
“remote control data block” that is used when a
remote control unit is connected. Paint
adjustment data is automatically selected and
output to the camera section depending on
whether or not a remote control unit, such as the
RM-B170, is connected.
When a remote control unit is connected, the
“remote control data block” is selected as the
current paint data block, and the paint adjustment
parameters that were in effect the last time the
remote control unit was used are recalled.
However, when the settings of absolute value
controls
1)
and absolute value switches
2)
are set
on the remote control unit, the settings on the
remote control unit override the settings on the
camcorder.
When the remote control unit is disconnected
from the camcorder, the “main data block” is re-
enabled, and the camcorder returns to the settings
that were in effect before the remote control unit
was connected.
Button
RM Rec Start setting
RM
Camera
PARA
Camcorder REC
START button
Disabled Enabled
Enabled
Lens VTR button Disabled Enabled
Enabled
ASSIGN. 1/3
switches,
ASSIGNABLE
4/5 switches, and
COLOR TEMP.
button
Disabled Enabled
Enabled
RM-B170/B750
VTR button
Enabled
Disabled Enabled
Main data block
Remote control data
block
Camera unit hardware
RM-B170 connected
RM-B170 not connected
Camcorder
setup menu
Camcorder non-volatile memory
RM-B170