3-30
CCU-700A
CCU-700AP
A
SYNC
A
BLKG
3-5-4. B-Y Crosstalk Adjustment
Rank
:
A
Note
:
Make sure that 45 MHz frequency on
the MD board (camera) is correct.
Equipment
:
Oscilloscope
To be extended
:
DM-94 board
Test point
:
TP17 (GND: E3)/DM-94 board
Adjusting point
:
1
RV13 (OFFSET ADJ)/DM-94
board
Specification
:
A = 0
±
3 mV
3-5-5. C 1st AGC Adjustment
Rank
:
B
Equipment
:
Oscilloscope
To be extended
:
DM-94 board
Preparation
• S1 (AUTO/MANU)/DM-94 board
→
“AUTO”
• S4 (C 2nd AGC)/DM-94 board
→
“OFF”
Test point
:
TP17 (GND: E3)/DM-94 board
Adjusting point
:
1
RV10 (C AGC CONT)/DM-94
board
Specification
:
A = 350
±
20 mV
3-5. CHROMA Cable Compensation System Adjustment