3-8-4. PGM Deviation Adjustment
Rank
:
C
Equipment
:
Spectrum analyzer, Oscilloscope,
Audio generator
To be extended
:
AT-88 board
Test point
:
TP5 (GND: E2)/AT-88 board
Adjusting point
:
1
RV81 (PGM DEV)/AT-88 board
Specification
:
A = B = 7.0
±
0.4 kHz
Adjustment Procedure
1.
Feed the 1 kHz sine-wave to pin D68 (X), pin A69 (Y)
and pin B69 (GND)/extension board (AT-88).
…Fig-2 (Refer to 3-1-4. Audio connection.)
2.
Adjust the output of audio generator so that the level at
TP44 (GND: E1) on the AT-88 board is 200 mV p-p.
3.
Connect the probe of the spectrum analyzer to TP5
(GND: E2) on the AT-88 board.
Adjust
1
RV81 (PGM DEV) on the AT-88 board so
that the A and B are 7.0
±
0.4 kHz.
3-8. TRIAX Interface System Adjustment
S1006 S1007
REMOTE MODE-1
REMOTE MODE-2
E1000
TP1001
TP22
TP23
S1001
MODE1
S1002
MODE2
TP21
E2
E20
TTL
POWER
S2822
TTL
S2792
CONTACT
POWER
S2821
G TALLY
S2791
Y TALLY
POWER POWER
RV2432
RV2431
S2081
RV2310
RV2382
TP47
TP48
E12
S2082 S2083
S2061
S2341
RV2301
RV2302
TP10
TP13
TP9
TP15
TP17
RV501
RV401
TP12
S301
RV201
RV301
LV1 LV21
TP1
TP2
TP7
RV101
RV81
LV81
RV61
LV61
RV41
LV41
TP5
TP4
TP3
TP6
T401
T501
TP16
TP14
TP11 TP8
LV101
TP45
TP44
E1
TP42
E11
TP46
S2491
ENG SELECT
S1004
S1003
S1005
S2301 S2062
TP43
TP40
E10
RV2342
RV2341
RV2451
RV2452
RV2491
RV2211
RV2212
RV2241
S2241
PROD SELECT
-
12
-
5
+5
+12
NORM
MIN
CH
-
1
NORM
MIN
CH
-
2 CLEAR
MIC LEVEL
CCU PAINT
REAR
INCOM MIC
DYNAMIC
CARBON
ENG
PRIVATE
PROD
PGM
MIX
INCOM
SELECT
SIDE
TONE
2W
LEVEL
2W
CANCEL
RTS
CANCEL
2W
LEVEL
2W
CANCEL
RTS
CANCEL
ENG
PROD
AT
S201
T301
T201
(PANEL SIDE) AT-88 BOARD (COMPONENT SIDE)
CENT FREQ : 4.3MHz
FREQ SPAN : 20MHz
Image of waveform