1-4
CCU-700A(UC)
CCU-700AP(CE)
3
2
1
7
6
4
5
12
11
9
8
10
16
14
13
15
18
17
19
INTERCOM/TALLY/PGM (19P, MALE)
(EXTERNAL VIEW)
(0 dBu=0.775 Vrms)
No.
Signal
Specifications
1
PGM (X) IN
-20 dBu/0 dBu
2
PGM (Y) IN
(Selectable with S2081/AT board)
3
PGM (G) IN
4
R TALLY (X) IN
ON: 24 Vdc, TTL (H), SHORT
5
R TALLY (Y) IN
OFF: 0 Vdc, TTL (L), OPEN
6
G TALLY (X) IN
ON: 24 Vdc, TTL (H), SHORT
7
G TALLY (Y) IN
OFF: 0 Vdc, TTL (L), OPEN
8
ENG (R) (X) OUT
ENG SYSTEM RECEIVE
9
ENG (R) (Y) OUT
0 dBu BALANCED
10
GND
CHASSIS GND
11
PROD (R) (X) OUT
PROD SYSTEM
12
PROD (R) (Y) OUT
RECEIVE 0 dBu BALANCED
13
ENG (T) (X) IN
ENG SYSTEM TALK
14
ENG (T) (Y) IN
0 dBu BALANCED
15
PROD (T) (X) IN
PROD SYSTEM TALK
16
PROD (T) (Y) IN
0 dBu BALANCED
17
ENG (G)
GND for ENG
18
NC
No connection
19
PROD (G)
GND for PROD
4
1
3
2
12+1 V
-6 V
R
G
B
DC 0 ± 2V
WF MODE (4P, FEMALE)
(EXTERNAL VIEW)
No.
Signal
Specifications
1
SEQ CONT OUT (G)
OPEN COLLECTOR
2
SEQ CONT OUT (X)
+ (PNP) /- (NPN)
(Selectable with S1102/VA board)
3
STAIR CASE OUT (X)
*
3)
4
STAIR CASE OUT (G) GND for STAIR CASE
*
3) Stair Case signal
REMOTE (8P, FEMALE)
RCP/CNU
AUX
(EXTERNAL VIEW)
No.
Signal
Specifications
1
TX (+)
CCU SERIAL DATA
2
TX (-)
3
RX (+)
*
4)
4
RX (-)
5
TX GND
GND for TX
6
POWER (+) OUT
RCP POWER, +30 V
7
POWER (-) OUT
GND for POWER
8
SPARE
CHASSIS GND
CHASSIS GND
*
4) RCP/CNU : RCP/CNU/BVP/MSU/VCS SERIAL DATA
AUX
: AUX SERIAL DATA
1
2
3
4
5
6
7
8
1-2. Connectors and Cable