User Manual for the Type 8300 Compatt 6
(and Variants)
UM-8300-Compatt 6
Issue B3
7. Click the
OPEN
or
CLOSE
button before the 30-second countdown ends.
8. After the
OPEN/CLOSE
button has been selected, it will return to a greyed out status and
Active
will appear to indicate the mechanism is moving.
9. When the release mechanism movement has completed the
OPEN/CLOSE
button indicates the
next position of the release mechanism.
10. If the release is in the
Open
position, it will be necessary to manually position the release into the
closed position.
11. Screw a long screw
(either an M4 or M5 screw – not supplied by Sonardyne) into the release
mechanism
; see
.
12. Unscrew the pin
from the ‘D’ shackle pin. With the aid of a screwdriver, push the release
mechanism into the closed position and insert the ‘D’ shackle pin
into the holes in the side of
the mechanism
to hold the Release in the closed position.
Section 9 – Functional Test
72