4. Operation 

 
When powered up, the AIS LIFEGUARD will emit a short beep and the Green and Red LEDs will quickly flash 
for about 1 second and then the Green LED will stay on. This is the normal state of the AIS LIFEGUARD and 
indicates that it is working correctly. 

Every time that a valid !AIVDM message is received from the AIS system, the Green LED will briefly flash which 
indicates that correct NMEA 0183 data communication is taking place. 

The AIS LIFEGUARD checks all MSG1 and MSG14 AIS Sentences to see if an AIS SART/MOB/EPIRB has 
been activated or tested. If it detects one of these conditions, then AIS LIFEGUARD alarms in the following way; 

ALARM TYPE 

RED LED 

INT BUZZER 

EXT BUZZER 

MUTE ALARM 

REAL 

CONTINUOUS 

CONTINUOUS 

CONTINUOUS 

MANUAL 

TEST 

FLASH x5 

BEEP x5 

SILENT 

AUTOMATIC 

 
A Real Alarm will cause all audible and visual alarm indications to occur and can only be “Muted” by someone 
pressing the Mute/Reset button. A short press of the Mute/Reset button will cause the Internal and External 
buzzers to silence but the Red Alarm LED will stay illuminated to show that an alarm condition has occurred and 
that the MMSI number of the SART that caused the alarm is stored in memory and will not cause another alarm. 

The AIS LIFEGUARD will alarm again if it detects another alarm message from a SART with a different MMSI 
number. The AIS LIFEGUARD can store up to 20 different MMSI numbers of SARTs that have activated the 
Alarm. Each time a SART makes the AIS LIFEGUARD alarm, the Mute/Reset button must be pushed to silence 
that particular alarm. 

After an emergency situation has finished and one or more alarms have occurred and been silenced by pressing 
the Mute/Reset switch, the AIS LIFEGUARD should be RESET to make it forget all of the previous MMSI 
numbers of SARTs that have triggered an alarm. To RESET the AIS LIFEGUARD, press and hold the 
Mute/Reset switch for 4 seconds until the Internal Buzzer beeps once and the RED Alarm LED goes out. 

Most AIS SARTs have a test mode and the AIS LIFEGUARD allows you to easily test the AIS SARTs before 
commencing a voyage. When the AIS LIFEGUARD detects a SART in test mode, it Beeps the Internal Buzzer 
and flashes the RED Alarm LED five times. If you have multiple AIS SARTs to test, it is recommended that you 
test them one at a time. Activate the AIS SART test mode, and at the end of the test, the AIS LIFEGUARD will 
beep and flash to indicate the test has worked, before automatically returning to normal operation. 

NOTE

 – the AIS LIFEGUARD has a Self-Test mode which is entered if you press and hold the Mute/Reset 

button whilst the AIS LIFEGUARD powers up. In Self-Test mode the two LEDs and the Internal and External 
buzzers are turned ON, which is useful for testing that everything is working correctly. To exit Self-Test Mode 
simply release the Mute/Reset switch.  

DIGITAL YACHT LTD

 

AIS LifeGuard Quick Start Guide

 

 

QUICK START AIS LIFE GUARD V1.00

 

 

 

Installation & Quick Start Guide 

AIS LifeGuard MOB Alarm 

 
 
 

 

 

1. Introduction 

Congratulations on the purchase of your AIS LifeGuard MOB Alarm. It is recommended that your this product is 
installed by a professional installer.  

 

Before operating the unit  you should familiarise  yourself with this Quick Start Guide and the 
user manuals for any equipment you wish to connect it to. 

2. Before you start 

You will need the following items and tools to complete and test the installation: 

 

The AIS LIFEGUARD 

 

A working AIS Receiver or Transponder with an NMEA 0183 Output 

 

An AIS SART 

 

External Buzzer (optional) 

 

Access to 12V or 24V DC power supply where the unit is to be installed. 

 

M3 or M4 screws or other fixings appropriate to the mounting location. 

 

 