3. Using a clean finger (not a brush), smear a light film of Vaseline all over the surface of the
O-ring only (do not smear Vaseline into the endcap grooves).
4. Fit the O-ring onto the endcap, ensuring that the O-ring is not twisted (the moulding line on the O-
ring, must be straight).
5. Always fit the outermost O-ring first, then roll the second O-ring over the first O-ring (this
minimises the risk of damaging the innermost O-ring).
6. Before assembly, apply a light even film of petroleum jelly to the O-ring mating surface (the
housing bore).
Note
There should be no visible lumps of petroleum jelly on the O-ring or the mating bore.
8.6 Scheduled Maintenance and Recalibration
To ensure the transponder provides long and effective service, it is important to carry out scheduled
maintenance and recalibration processes.
identifies the scheduled maintenance and the frequency of the activity.
Section 8 – Maintenance