User Manual for the Type 8300 Compatt 6
(and Variants)
UM-8300-Compatt 6
Issue B3
Depth Measurement (High Precision Strain Gauge)
Resolution
0.01 kPa
0.01 kPa
0.01 kPa
0.01 kPa
0.01 kPa
Accuracy
±0.5 m
±0.3 m
±0.1 m
±0.05 m
±0.03 m
Depth Measurement (Digiquartz
®
option)
Span (pressure psi)
0 – 6000 psi
0 – 3000 psi
0 – 2000 psi
Span (pressure kPa)
0 – 41370 kPa
0 – 20685 kPa
0 – 13790 kPa
Span (depth)
0 - 4100 m
0 - 2050 m
0 - 1360 m
Resolution
0.01 kPa
0.01 kPa
0.01 kPa
Accuracy
±0.42 m
±0.21 m
±0.14 m
Options I2 an I4 dual axis high accuracy. (Inclinometer I4 option is inverted for transponders
mounted upside down)
Range
±90°
Resolution
0.01° (over the range ±14.5°)
0.05° (over the range ±45°)
Accuracy
±0.05° (over the range ±14.5°)
±0.2° (over the range ±45°)
Tilt Switch
Internal 45° tilt switch indicates vertical position
Sound Sensor
Model
50 mm
100 mm
Resolution
0.01 m/s
0.01 m/s
Range
1400–1600 m/s
1400–1600 m/s
Accuracy
±0.06 m/s
±0.03 m/s
13.11 Responder Input Trigger (Sync Input)
Inactive State
Low
Ground Reference
Power Ground
Input Impedance
~47 kΩ
Trigger Pulse
Nominally positive pulse minimum 4.5 V, maximum 24 V. Leading edge
triggered
Responder mode is enabled by serial or acoustic command
Pulse Width
See
Section 6.2.1 "Responder Mode"
Turn Around Delay
TAT reported by CS Command is used for IRS replies. HPR replies have a
fixed TAT of 30 ms
Blocking Time
TAT + BLK as reported by CS Command
Section 13 – Technical Specifications