Assigning a zone to the intrusion detectors
1/ Open the covers of the intrusion detectors
(opening detectors and movement detectors)
2/ Determine the location of the devices and
set up the zones for the detectors
For each intrusion detector (movement detectors and opening detectors), the
monitored zone and triggering mode are defined using switches located inside
these products. They must be configured when the corresponding device
is installed.
Movement detectors
are supplied set for
zone C, immediate triggering
.
Opening detectors
are supplied set for
zone AD, triggering
delayed
by
45 seconds before activation of the alarm in order to allow sufficient time to enter
and disarm the system if there is an opening detector positioned at the front
door.
To customise this option, position switches 1 and 2 as follows:
3/ Adjust the switches on the intrusion
detectors to assign them to a zone
Record the zone selection on the
memo sheet
in the operating manual.
Select
zone – trigger mode
Position of
switches
What happens in the event of intrusion
(in part or full mode)
AD -
delayed triggering
Activation of sirens is
delayed
(after the entry delay).
+
Telephone transmission of one or more alarm
messages.
A - immediate triggering
The indoor siren is activated
immediately
.
+
The outdoor siren with flash is activated after
10 seconds.
+
Telephone transmission of one or more alarm
messages.
B - immediate triggering
C - immediate triggering
Do not touch the switches on the water leakage and power
detectors.
L
OCATION
OF SWITCHES
If the installation includes the central
unit/phone dialer version with Internet
access, it is also possible to configure the
alarm system and assign a zone to an
intrusion detector by computer (see the
supplementary manual).
In this case, the zone settings
made by computer overrule the
switch settings made inside the intrusion
detectors.
■
9
■