Table of specifications
■
54
■
Device
Use
Operating
temperature
Tamper
switch
Action
Indoor siren
Indoor
+ 5 to + 40 °C
Opening
Removal
■
Triggers a low level alarm for 10 seconds (95 dB) followed by 110 seconds
at full power (112 dB) or triggering of the alarm for 2 minutes at low level
95 dB depending on the settings.
Outdoor siren
with flash
Outdoor
under
cover
- 25 to + 55 °C
Opening
Removal
■
No acoustic alarm triggered for 10 seconds then low level alarm for
10 seconds (90 dB) then 100 seconds at full power (108 dB). Flash
triggered for 120 seconds.
LCD keypad
Indoor
+ 5 to + 40 °C
Opening
Removal
■
Provides visual information on commands.
■
Ability to view event log.
■
Direct command of alarm or automatic devices via
the
and
keys.
Control keypad
Indoor
+ 5 to + 40 °C
Opening
Removal
■
3 types of system part arming, full arming and disarming.
Movement detector
Indoor
+ 5 to + 40 °C
Opening
■
Radius of action of 10 metres with an angle of 90 °.
Movement detector for
small pets
Indoor
- 10 to + 50 °C
Opening
■
Radius of action of 12 metres with an angle of 85 °.
Movement detector for
big dogs
Indoor
+ 5 to + 40 °C
Opening
■
Radius of action of 12 metres with an angle of 110 °.
No detection between the floor and the detector.
Outdoor movement
detector
Outdoor - 25 to + 50 °C
Opening
■
Radius of action dependent on settings: see the detector.
IP camera
Indoor
0 to + 50 °C
-
■
Detection angle: 47°
■
Min. illumination: 1 lux (does not operate in the dark)
■
Light sensitivity: 10,000 lux
■
360° adjustable stand
Opening detector
Indoor
- 10 to + 55 °C
Opening
■
Maximum distance between magnet and detector of 10 mm on wood
and 5 mm on soft metal.
Opening and glass
breakage detector
Indoor
- 10 to + 55 °C
Opening
■
Detects the breaking of glass and the opening of a window.
Garage door opening
detector
Indoor
- 10 to + 55 °C
Opening
■
Detects the opening of a garage door.
Roller shutter opening
detector
Indoor
- 10 to + 55 °C
Opening
■
Detects a 5 cm upward movement of the last shutter strip.
Audiosonic glass
breakage detector
Indoor
+ 5 to + 40 °C
-
■
Detects the breaking of glass in external windows only.
Smoke detector
Indoor
+ 5 to + 40 °C
-
■
Detects the presence of smoke near the detector. It is essential to fix it to
the ceiling.
Water leakage
detector
Indoor
+ 5 to + 40 °C
-
■
Detects the presence of water at the electrodes.
Power
detector
Indoor
+ 5 to + 40 °C
-
■
Detects any power failure.
Remote controls
Indoor
+ 5 to + 40 °C
-
■
Arms/disarms the system.
■
Provides visual information on commands (depending on model)