DKC400Y AC Sliding Gate Installation Manual www.solavis.com.au
Copyright © 2008 SOLAVIS
™
Doc: DKC400Y Installation Manual v1.1 page 15 of 22
Verify open direction
:
If the gate does not move in the desired direction, then you will need to reverse the motor
operating direction. Open the black plastic
case and exchange wires ‘V’ with ‘W’, and also
exchange wires
‘OP’ with ‘CL’.
Table 1 DIP-switch
(See Fig.6 terminal 5)
Position DIP-switch
Function
1
ON
Limit switch mode is NC.
OFF
Limit switch mode is NO.
2
ON
Auto-close function and auto-close function of pedestrian mode
are available.
OFF
Both Auto-close function and auto-close function of pedestrian
mode are shut off.
3
ON
Programming / In this position the control board is in
programming condition, DO NOT leave it in this position for
normal operation.
OFF
Normal / In this position the control board can be normally used.
Set auto-close function
This feature can be selected to make the gate stay open for some seconds before it
automatically closes. The auto-close time can be adjusted to between 0 and 44 seconds
Please turn the second and the third DIP-switch (See Fig.6 terminal 5) to the ON
position.
Press the remote control button (button 1, button 2 or button 3) that has been
programmed to open the gate (see
Verify open direction
section).
Stop the gate at any position by pressing the same button, pause for how long you
want your gate to stay open before automatically closing. This is called the auto-
close time. The range is between 0-44 seconds.
Close the gate by pressing the same button. Press the button again to stop the gate
or let the gate stop at its closed position automatically if the limit switch is reached.