DKC400Y AC Sliding Gate Installation Manual www.solavis.com.au
Copyright © 2008 SOLAVIS
™
Doc: DKC400Y Installation Manual v1.1 page 12 of 22
9.
Limit switch:
CL (Close limit), CO (Com), OP (Open limit)
,
DC12V (Output power
supply)
CL
COM
OP
N.C. (For N.C. limit switch)
CL
COM
OP
N.O. (For N.O. limit switch)
Limit switch mode is adjustable by DIP-switch. (See table 1)
Schematic diagram
Control board
Motor wiring
terminal
E
W
V
C
C
U
OP
COM
CL
MOTOR
REED SWITCHES
SWITCH
W
V
COM/U
OPEN
COM
CLOSED
RELEASE
X9
Wiring diagram
10.
Output power supply
: +12V (DC +12V), COM (CO)
,
DET (Loop detector), I.R.
(Infrared N.C)
COM
GND
+12V
Out
COM
I.R
COM
+12V
Terminal
X8, No.10
Terminal
X8, No.10
I.R
COM
Out
COM
AC24V
AC24V
Terminal
X5,No.11
Infrared
Control board
Infrared
Control board
Infrared with DC input
Infrared with AC input
Loop detector with DC input
Control board
Loop detector
Terminal
X8, No.10
+12V
COM
DET
COM
Out
+12V
GND
COM
Loop detector with AC input
Control board
Loop detector
Terminal
X5,No.11
AC24V
AC24V
COM
Out
COM
DET
Terminal
X8, No.10
Schematic diagram