Страница 1: ...IS VITAL FOR THE SAFETY OF ALL PERSONS INSTALLING AND USING THIS OPENER TO FOLLOW THE INSTALLATION INSTRUCTIONS AND SAFETY WARNINGS FAILURE TO COMPLY MAY RESULT IN SERIOUS PERSONAL INJURY AND OR PROPERTY DAMAGE AND FAILURE OF THE OPENER SYSTEM ...

Страница 2: ... a digital map of the door travel cycle DC motor Low noise soft start soft stop ensures smooth operation and longevity LED display Working situation can be shown on the LED screen Decoding Rolling code secure radio transmission Manual Disengagement Open and close the door by hand in the event of a power cut Optional Functions Photo beam battery backup wall button and flash light 2 Technical Specif...

Страница 3: ...5W Open and close force 1200N 1500N Courtesy light time 3 minutes 3 Installation 3 1 Recommended Tools 3 2 Installing the Operator and Rail NO Tools 1 Drill 2 Step ladder 3 Ratchet 4 Tape measure Carpenter s level 5 Screwdriver 6 Tongs 7 Neon electroscope multimeter 8 Adjustable wrench 9 Hammer ...

Страница 4: ...4 4 Control panel and Transmitter ...

Страница 5: ...5 Button 1 Button 2 Button 3 Button 4 5 Optional Terminals and Connections ...

Страница 6: ...6 6 Programming the Operator 6 1 Preparing ...

Страница 7: ...m 99 to 11 Then the operator turns to standby mode Turn on the power The LED displays from 99 to 11 At last it displays 6 2 Setting Open and Close Positions Press and hold SET until it displays P1 press SET it displays OP Then press UP when the door has reached the open position press SET It displays CL then press DOWN it displays CL When the door has reached the closed position press SET The door...

Страница 8: ...E it displays Su press a button on the transmitter then release and press the same button again Su flashes then it displays to show setting is complete Repeat up steps to code a maximum of 20 different transmitters and or buttons 6 4 Force Adjustments Press and hold SET it displays P1 press UP once it displays P2 press SET once again it will show the current situation Press UP to increase the forc...

Страница 9: ... beam device please make sure it displays H0 to close this function 6 6 Auto Close ON OFF Press and hold SET it displays P1 press UP three times it displays P4 Press SET to show current situation Press UP to increase the Auto close one minute and press DOWN to decrease one minute Maximum degree is b9 and minimum is b0 Press SET to confirm The default setting is b0 bo shows auto close off 6 7 Lock ...

Страница 10: ...to confirm the function you need 7 Owners Guide 7 1 Attention in use 7 1 1 Use the transmitters only when door is in sight Do not stand or walk under a moving door The transmitters should be kept out of reach of children 7 1 5 Check at least twice a year to make sure the door is properly balanced and that all working parts are in good working condition Have the door professionally serviced annuall...

Страница 11: ... open and close positions The door can t be closed Photo beam function is enabled Door obstruction Cancel the photo beam function check obstruction The wall button works well but the transmitter doesn t work No transmitter learning Transmitter battery is low Code referring to 6 3 Change transmitter battery Too short of transmitter distance The transmitter battery is low Change transmitter battery ...

Страница 12: ...ees that they may be charged a call out fee plus any parts required to complete the repair Liability Australia only Under no circumstances shall the Seller be liable for consequential incidental or special damages arising in connection with the use or inability to use the Unit In no event shall the Seller s liability for damages or injury arising from breach of law or contract or for negligence ex...

Страница 13: ...__________ Date______ ______ _______ Contact Details __________________________________________________________________________________ Notes____________________________________________________________________________ __________________________________________________________________________________ ...