-46-
No.
Name
Detail
display
Detail name
Stop method (Note 2, 3)
W
a
rn
ing
91
Servo amplifier overheat
warning (Note 1)
91.1
Main circuit device overheat warning
92
Battery cable disconnection
warning
92.1
Encoder battery cable disconnection warning
92.3
Battery degradation
95
STO warning
95.1
STO1 off detection
DB
95.2
STO2 off detection
DB
96
Home position setting
warning
96.1
In-position warning at home positioning
96.2
Command input warning at home positioning
9F
Battery warning
9F.1
Low battery
9F.2
Battery degradation warning
E0
Excessive regeneration
warning (Note 1)
E0.1
Excessive regeneration warning
E1.1
Thermal overload warning 1 during operation
E1.2
Thermal overload warning 2 during operation
E1.3
Thermal overload warning 3 during operation
E1
Overload warning 1 (Note 1)
E1.4
Thermal overload warning 4 during operation
E1.5
Thermal overload error 1 during a stop
E1.6
Thermal overload error 2 during a stop
E1.7
Thermal overload error 3 during a stop
E1.8
Thermal overload error 4 during a stop
E2
Servo motor overheat
warning
E2.1
Servo motor temperature warning
E3
Absolute position counter
warning
E3.2
Absolute position counter warning
E3.5
Encoder absolute positioning counter warning
E4
Parameter warning
E4.1
Parameter setting range error warning
E6
Servo forced stop warning
E6.1
Forced stop warning
SD
E7
Controller forced stop warning
E7.1
Controller forced stop warning
SD
E8
Cooling fan speed reduction
warning
E8.1
Decreased cooling fan speed warning
E8.2
Cooling fan stop
E9.1
Servo-on signal on during main circuit off
DB
E9
Main circuit off warning
E9.2
Bus voltage drop during low speed operation
DB
E9.3
Ready-on signal on during main circuit off
DB
EC
Overload warning 2 (Note 1)
EC.1
Overload warning 2
ED
Output watt excess warning
ED.1
Output watt excess warning
F0
Tough drive warning
F0.1
Instantaneous power failure tough drive
warning
F0.3
Vibration tough drive warning
F2
Drive recorder - Miswriting
warning
F2.1
Drive recorder - Area writing time-out warning
F2.2
Drive recorder - Data miswriting warning
F3
Oscillation detection
warning
F3.1
Oscillation detection warning
Note 1. Leave for about 30 minutes of cooling time after removing the cause of occurrence.
2. Stop method indicates as follows:
DB: Stops with dynamic brake. (Coasts for the driver without dynamic brake.)
SD: Decelerates to a stop
3. This is applicable when [Pr. PA04] is set to the initial value. The stop system of SD can be changed to DB using [Pr. PA04].