-11-
[LECSS]
Series
LEY25/LEYG25
LEY25D/LEYG25D
LEY32/LEYG32
LEY32D/LEYG32D
Lead symbol
A
B
C
A
B
C
A
B
C
A
B
C
Lead
12
6
3
12
6
3
20
10
5
16
8
4
Parameter
Para.
No
Initial
value
Recommended value
Regenerative option
PA02
0000
0000 (Non)/ 0002 (LEC-MR-RB032)
Rotation direction
selection
PA14
0
0
(+
:
Counter
motors side)
1
(+
:
Counter
motors side )
0
(+
:
Counter
motors side)
1
(+
:
Counter
motors side )
Adaptive tuning mode
PB01
0000
0000
Load to motor inertia
moment ratio
PB06
7
7
Machine resonance
suppression filter 1
PB13
4500
4500
Notch shape selection 1
PB14
0000
0000
Series
LEY63
LEY63D
Lead symbol
A
B
C
L
A
B
C
Lead
20
10
5
5(2.86)
(Pulley
raito 4/7)
20
10
5
Parameter
Para.
No
Initial
value
Recommended value
Regenerative option
PA02
0000
0000 (Non)/ 0002 (LEC-MR-RB032)/ 0003 (LEC-MR-RB12)
Rotation direction
selection
PA14
0
0
(+
:
Counter motors side)
1
(+
:
Counter motors side )
Adaptive tuning mode
PB01
0000
0000
Load to motor inertia
moment ratio
PB06
7
7
Machine resonance
suppression filter 1
PB13
4500
4500
Notch shape selection 1
PB14
0000
0000
*1 Parameter is the recommended value. Please change the parameter to make appropriate value for your
operating method.
*2 A mechanical resonance may occur depending on the configuration or the mounting orientation of the
transferred object. Please change the parameter in the initial setting.
* For LECSS, please set the electronic gear with PC, PLC etc. in your application.