IDX-OM-M051
Air Dryer
3.Start and stop
3.1 Before Starting
3 - 1
IDF100F~150F-W
Caution
Only people who have sufficient knowledge and experience about the product and its
accessories are allowed to start and stop the product.
3.1 Before Starting
Check the following items before performing a trial run of the product.
•
Installation
conditions
Check visually that the product is installed horizontally.
Ensure the product is fixed firmly by the anchor bolts.
Do not place any heavy object on the product, or apply excessive force to the product by the external
piping.
•
Connection of cables
Check the power supply and signal cables and ground are correctly connected.
•
Drain tube
Check proper connection of the drain tube.
•
Pneumatic piping
Check proper connection of pneumatic piping. Ensure the valves at the inlet and outlet and bypass of the
product are completely closed.
•
Ball valve
Check the ball valve of the auto drain is open.
•
Check the ground fault circuit interrupter built into the product is turned on if option R is selected.
•
Facility water piping
Check proper connection of pneumatic piping. Make sure that the IN and OUT sides of the equipment
are open, and the valve of the by-pass piping is closed.
3.2 Start
Start the product by the following procedure.
1) Operate the facility water equipment and open the valve to supply the facility water to this equipment.
2) Turn on the main power supply. Then, turn on the switch with lamp.
For remote operation, turn on the external switch as well.
3) The lamp will light up and the automatic water supply valve in the equipment will open a while later,
and facility water will be supplied. .
4) Slowly open the compressed air IN side valve fully. Ensure the bypass valve is completely closed.
Check there is no air leakage.
5) After the pneumatic pressure gauge reaches the specified pressure of the air compressor, slowly
open the valve at the outlet fully.
Start and stop
3