IDX-OM-M051
Air Dryer
2. Transportation and installation
2.2 Installation
2 - 8
IDF100F~150F-W
2. Pass the power supply cable through by using the cable fixture at the right bottom base of the product,
and connect it to the terminal block.
(Refer to the label on the terminal block.)
M4 tightening torque: 1.4 to 2.0Nm
∗
Option R: M5 tightening torque: 2.6Nm
Fix the cable with a cable tie as shown on page 2-8.
Do not touch equipment other than the terminal block during wiring.
3. If you are not performing wiring for operation, error signal and remote operation, put back the front panel.
[Wiring for operation, error signal and remote operation]
Specifications of signal cable
Prepare the following cable.
Cable: 0.5mm
2
(20AWG), Cable outside diameter: 17mm or less, 6 cores 0.5mm
2
Approx. 0.9m is necessary to route the internal wiring of the product.
Signal cable length
The signal cable length from the product should be less than 30m.
Terminal block (refer to “1.3 Name and function of parts” for details).
Connect the signal cable to the terminal block on the left. The connection size is M3.
Applicable crimped terminal width: 6.5mm or less
[Wiring procedure]
1. Remove the front panel of the product.
2. Take out the signal cable from the signal cable entry at the right bottom base of the product, fix it to the
steel plate at the back with a cable bushing, etc. and connect it to the terminal block.
(Refer to the label on the terminal block.) M3 tightening torque: 0.63 to 1Nm.
Do not touch equipment other than the terminal block during wiring.
3. Put back the front panel.
[Remote operation]
∗
Voltage is applied to the terminal block. Be sure to turn off the switch with lamp before wiring.
1) Disconnect the wires from no. 5 and 6 of the terminal block and mount the external switch.
- The external switch used for remote operation should be an alternate type (no voltage
dry contact).
2) For remote operation, with the switch with lamp turned on, turn the external switch on and then off.
- In remote operation, the product cannot be started up from the operation panel.
- When the product is to be stopped during remote operation, turn off the switch with lamp.
Signal cable
Power supply cable