4. Checks and Inspection
4.2 Parts requiring regular maintenance
4 - 8
IDF100F~150F-W
4.2.3 Maintenance of timer type solenoid valve with auto drain (Option V)
As a preventive maintenance, clean the built-in strainer regularly.
[Cleaning of built-in strainer]
•
Do not turn off the switch with lamp. (Electricity is used.)
•
Fully open the valve for pneumatic piping.
•
The bypass valve needs to be opened during this work when the compressed air is necessary.
1. Remove the rear panel and check the ball valve is closed.
2. Press the flush button and then the test switch to release the internal air pressure of the auto drain.
3. Remove the strainer cap and take out the built-in strainer and clean.
4. Put back the built-in strainer and its cap and open the valve at the inlet of condensate, and check there
is no leakage before using.
4.2.4 Maintenance of operating time accumulator
The operating time accumulator uses a lithium battery. The referential life of the battery is 7 years (at 25
o
C).
This life is not guaranteed.
If the display is flashing or off, the battery has reached the end of its life, and needs to be replaced.
Please purchase a commercially available button battery Y92S-36/OMRON or CR2477/Panasonic.
The replacement of the battery will reset the display to zero. It is useful to record the time displayed before
the replacement.
[MEMO]
Date
Running time display (h)
Accumulated time (h)