-13-
No.D-
※
S-OMG0006-C
Mounting and Installation
■
Wiring
Connections should only be made with the power supply turned OFF.
Use separate routes for the product wiring and any power or high voltage wiring. Otherwise, malfunction
may result due to noise.
Ensure that the FG terminal is connected to ground when using a commercially available switch-mode
power supply. When a switch-mode power supply is connected to the product, switching noise will be
superimposed and the product specification can no longer be met. This can be prevented by inserting a
noise filter, such as a line noise filter and ferrite core, between the switch-mode power supply and the
product, or by using a series power supply instead of a switch-mode power supply.
●
Connecting the wiring
Attaching the sensor connector to the sensor wire
Strip the sensor wire as shown. Do not cut the insulator.
Insert the corresponding wire colour shown in the table into the pin number printed on the sensor connector,
to the bottom.
Pin number on connector
Wire colour
Contents
1
Black
SOUT1
2
Blue
GND
3
White
SOUT2
4
Brown
Vsw
Check that the above preparation has been performed correctly, then part A shown should be pressed in by
hand to make temporary connection.
Part A should then be pressed in using a suitable tool, such as pliers.
The sensor connector cannot be re-used once it has been fully crimped.
In cases of connection failure such as incorrect order of wires or incomplete insertion, please use a new
connector. (ZS-28-C-1)