-12-
No.D-
※
S-OMG0006-C
■
Definition and terminology
Terms
Meaning
2
2-colour indication
Indication in which a red light is
ON in the operating position, and
a green light is ON in the
optimum operating range.
H
Hysteresis
The difference between the
points where the product turns
ON and OFF, which is provided
to prevent chattering.
I
Internal voltage drop
The voltage applied between the COM and signal line when the product turns ON.
L
Load current
The current flowing to the load when the product turns on.
M
Most sensitive position
The centre position of the sensor (which provides the strongest reaction from the
sensor), and also the centre position of the operating range.
N
Non-polarity
A 2-lead wire type of connection for which polarity is not important.
For example the load can be connected to either of (+) or (-).
S
Sequence controller
(PLC)
A device which performs sequence control, such as receipt of inputs from the
product along with programming and sending of the output to other equipment.
Solid state Auto switch
Product which generates ON and OFF outputs with or without mechanical contact
by using for example a transistor.