-24-
No.D-
※
S-OMG0006-C
Verification of the work piece
OUT1 output
(Detects the upper limit of the work piece)
OUT2 output
(Detects the lower limit of the work piece)
[A]
Work piece size is
correct
(Conformant range)
ON
(Work piece is smaller than the upper limit.
Conformance)
ON
(Work piece is larger than the lower limit.
Conformance)
[B]
Work piece is too
small
ON
(Work piece is smaller than the upper limit.
Conformance)
OFF
(Work piece is smaller than the lower limit.
Non-conformance)
[C]
Work piece is too
large
OFF
(Work piece is larger than the upper limit.
Non-conformance)
ON
(Work piece is larger than the lower limit.
Conformance)
[D]
No work piece
OFF
(Work piece is larger than the upper limit.
Non-conformance)
OFF
(Work piece is smaller than the lower
limit. Non-conformance)
: The dimension for [A] should be 0.5 mm minimum in the stroke direction.