3. Overview, functional description
X
X
X
X
6
6
Fig. 9
Consolidation of volumes
Block metering devices distribute a quantity
of lubricant delivered by a pump to multiple
outlets at the same volumetric ratio.
Different output quantities within a meter-
ing device are achieved by consolidating two
or more outlets.
For grease systems with a main meter-
ing device and secondary metering device,
check valves must be used on the metering
device outlets of the main metering device.
Opposite outlets can be consolidated by re-
moving a blind screw. Additionally, optional
crossporting bars can be attached to con-
solidate neighboring outlets.
T (twin) = two outlets
S (single) = one outlet
C (crossporting)
Consolidation of the four piston displacements to form one
outlet
Borehole
Plug screw