EN
6. Assembly
- 54 -
951-180-083-EN
Version 02
VP dimensions
Thread connection
VPM
Inlet:
M14×1.5
Outlet:
M10×1
VPG
G1/4"
G1/8"
Type
Number of
progressive
metering
device
sections
Number
of possible
outlets
L1
L2
Weight
[mm]
[mm]
[kg]
VPM-3 / VPG-3
3
6
84
98
1.73
VPM-4 / VPG-4
4
8
104
118
2.1
VPM-5 / VPG-5
5
10
124
138
2.47
VPM-6 / VPG-6
6
12
144
158
2.84
VPM-7 / VPG-7
7
14
164
178
3.21
VPM-8 / VPG-8
8
16
184
198
3.58
VPM-9 / VPG-9
9
18
204
218
3.95
VPM-10/VPG-10
10
20
224
238
4.32
The specified torques must be observed during
assembly and repair.
Tie-rod (starter plate)
(M8)
2.4 Nm ± 0.1 Nm
Nut for tie-rod
(M8)
12 Nm ± 1.0 Nm
Inlet and outlet fittings
Type of fitting
Sealing with O-ring
10 Nm ± 1.0 Nm
Sealing with EOlastic ring
10 Nm ± 0.1 Nm
Sealing with copper or alu-
minum ring
15 Nm ± 1.5 Nm
Sealing by
sealing edge,
with Loctite 243
15Nm ± 1.5 Nm
Sealing with
Conical nipple
1
)
15Nm ± 1.5 Nm
Plug screw M10
10Nm+1 Nm
1) Minimum of 9 Nm at drying time of
> 1h sufficient
6.3.2 VP tightening torques
NOTICE