![SKF LINCOLN VP Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/skf/lincoln-vp-series/lincoln-vp-series_operating-instructions-manual_1287102011.webp)
1
- 11 -
951-180-083-EN
Version 02
EN
1. Safety instructions
○
Use in areas with damaging radiation
(e.g., ionizing radiation)
○
Use to feed, forward, or store hazardous
substances and mixtures as defined in
Annex I Part 2-5 of the CLP Regulation
(EC 1272/2008) that are marked with
hazard pictograms
GHS01-GHS 09
○
Use to feed / forward / store gases,
liquefied gases, dissolved gases, va-
pors, or fluids whose vapor pressure
exceeds normal atmospheric pressure
(1013 mbar) by more than 0.5 bar at
their maximum permissible operating
temperature
○
Use in an explosion protection zone
○
Use to feed, forward, or store lubricants
with solvents
○
Use in potentially explosive gases and
vapors whose ignition temperature is
less than 125% of the maximum surface
temperature
○
Use in potentially explosive dusts whose
minimum ignition temperature and glow
temperature are less than 150% of the
maximum surface temperature
○
Use in another, more critical explosion
protection zone
○
Use with a damaged, missing, or improp-
erly performed subsequent ATEX finish
1.5 Painting plastic components
The painting of all plastic components and
seals of the products described here is
prohibited.
Completely remove or mask affected com-
ponents before painting the main machine.
1.6 Modifications to the product
Unauthorized modifications and changes
can have an unpredictable effect on safety.
Unauthorized modifications and changes
are therefore prohibited.
1.7 Prohibition of certain activities
Содержание LINCOLN VP Series