6. Assembly
- 66 -
951-180-083-EN
Version 02
6.4.8 Consolidation of multiple outlets on the VPK (crossporting)
• If individual sections on progressive
metering devices of series VPKM need to
be replaced with sections with different
metering;
• A metering device is to be supplemented
with additional sections;
• A metering device is to be cleaned/re-
paired, then they must be disassembled
and later consolidated again.
NOTICE
Two neighboring outlets are consolidated
from the end section towards the inlet
section.
NOTICE
Outlets of a progressive metering device
that are not needed must not be closed
because this will cause the metering device
to block. Consolidate unneeded outlets as
described with a neighboring outlet or con-
nect them to the pump via the return line.
Changing the number of sections and/or
metering rate of individual sections while
retaining the same quantity of grease sup-
ply changes all lubrication quantities of the
outlets.
- See Figure 23
Twin sections of a metering device have a
plug for crossporting.
The volumetric flow of an outlet can be
consolidated with other outlets as desired by
removing the corresponding plug.
This way, two or more outlets of an entire
metering device side can be combined
as long as there is no single section in-
between. The single section completes the
group formation; a new group can only be
formed behind the single section. Should it
later be necessary to separate the quantity
of two neighboring outlets, for example
due to an additional lubrication point, then
this can be done without difficulty. The plug
917-006-101 merely needs to be screwed
back in and the previously closed outlet con-
nected to the lubrication point.
Crossportings are typically necessary when: