![SKF LINCOLN VP Series Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/skf/lincoln-vp-series/lincoln-vp-series_operating-instructions-manual_1287102057.webp)
6
EN
6. Assembly
- 57 -
951-180-083-EN
Version 02
6.3.7 Assembly of the VP progressive metering device
used to fasten the unit, the screws must
have a minimum length of 40 mm.
Fastening material to be provided by the
customer:
o Hexagon head screws (3x) according to
EN ISO 4017, M6 -8.8
• Drill assembly holes (M6) acc. to the as-
sembly drawing and the conditions on
the surface.
• Clean surface to remove drilling chips.
• Place the progressive metering device on
the surface and roughly align it.
• Pass hexagon head screws (3x) according
to EN ISO 4017, M6 -8.8
through fixing
holes on the progressive metering device
and apply the screws to the M6 threads
of the surface.
• Gently tighten hexagon head bolts (3x).
• Align the progressive metering device
and tighten the hexagon socket head cap
screws diagonally with a torque of 9 Nm.
If necessary:
Tighten the inlet port screws
• Apply inlet port screws to the metering
device inlet and tighten with the pre-
scribed torque (Chapter 6.3.2).
• Tighten the outlet port screws.
• Apply outlet port screws or SKF quick
disconnect couplings to the threads of
the outlet bores and tighten with the
prescribed torque (Chapter 6.3.2).
-See Chapter 6.3.1, Figure 11
NOTICE
In case of installation on moving machine
parts or in case of strong vibrations (e.g.,
on pressing machines), self-locking screws
or a locking adhesive should be used for
installation of the metering device.
• Check the parallelism of the surface on
which the component is to be installed.
Stress-free installation of the component
must be ensured.
• Check for any fouling on the threaded
holes for metering device installation and
on the surface on which the component
is to be installed, and clean if needed.
The progressive metering device is installed
using 3x M6 screws. If M6 tapped bores are
Содержание LINCOLN VP Series
Страница 113: ...16 Appendix 16 EN 113 951 180 083 EN Version 02 16 Appendix 16 1 Declaration of Conformity proximity switch...
Страница 115: ...115 951 180 083 EN Version 02 Notes...
Страница 117: ......