![SKF LINCOLN VP Series Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/skf/lincoln-vp-series/lincoln-vp-series_operating-instructions-manual_1287102045.webp)
4
EN
4. Technical data
- 45 -
951-180-083-EN
Version 02
4.2.4 VPK progressive metering device with inductive NAMUR sensor
VPK with inductive NAMUR sensor, Table 10
VPK progressive metering device with inductive NAMUR sensor
For further technical data, see VPK basic design
Inductive NAMUR
sensor
Namur DIN EN 50227
/ Order number 24-1884-2288
Note!
Connection to certified intrinsically safe electrical circuits with maximum values:
U = 15 V / I = 50 mA / P = 120 mW
Connection to switching amplifier: Yes
Internal thread
M12x1
Design
PVC, with 2 m cable, 2x 0.34 mm
2
Nominal sensing
distance
4 mm
Output function
Contact normally closed (NC)
Rated voltage
8.2 VDC (1kΩ)
Supply voltage
7.5 to 30 VDC (when used outside a potentially explosion
environment)
Power consumption
< 1 mA (blocking; conducting: > 2.1 mA)
Switching frequency DC
1500 [Hz]
Electrical design
NAMUR
Internal capacitance
< 140 nF
Internal inductance
< 130 µH
Housing material
Housing material brass, specially coated
Approval
PTB 01 ATEX 2191
EX protection class of VPK progressive metering device with inductive NAMUR sensor
Device labeling
II 1G IIC T6 Ga / -20...+70°C
II 1D IIIC T90°C Da / -20...+70°C
Содержание LINCOLN VP Series
Страница 113: ...16 Appendix 16 EN 113 951 180 083 EN Version 02 16 Appendix 16 1 Declaration of Conformity proximity switch...
Страница 115: ...115 951 180 083 EN Version 02 Notes...
Страница 117: ......