1. Safety instructions
writing by an inspector from a recognized
validation organization. The repair is
marked by a repair sign on the machine
containing the following information:
- Date
- Executing company
- Type of repair
- If applicable, mark by expert
○
Shipping damage may lead to the loss of
explosion protection. If there is apparent
shipping damage, do not install or put
into operation the product.
○
All parts of the grounding concept must
be properly present and connected with
the main machine.
○
Handle materials in such a way that no
sparks may arise from tilting, dropping,
slipping, rubbing, or striking. If necessary,
cover materials by appropriate means.
○
Never disconnect plug-in connections
under electrical voltage. Secure plug-in
connections against disconnection by
hand using the locking clips provided
○
The operator must critically examine
whether operation without an empty
signal results in a new hazard potential
(e.g., due to heating of bearings on the
machine being lubricated to the range
of the ignition temperature in case of
lubrication failure). If this cannot be reli-
ably excluded, an empty signal must be
provided or appropriate organizational
measures taken to monitor the tempera-
ture of the bearings.
○
Avoid / immediately remove any accu-
mulated dust. Accumulated dust has a
thermal insulating effect and promotes
the formation of a potentially explosive
atmosphere when agitated/swirled.
○
The product must be integrated into the
operator’s lightning protection scheme.
○
All parts must be inspected for corrosion
on a regular basis. Replace affected parts
○
Junction boxes must be securely closed
and the cable glands properly sealed.
○
Any additional electrical monitoring
equipment must be securely connected
and correctly configured.