4
EN
4. Technical data
- 43 -
951-180-083-EN
Version 02
4.2 Volume data for VPK metering device sec-
tions
4.2.1 Basic design of VPK progressive metering device
Volume data for VPK metering device sections, Table 6
Max. inlet volumetric flow 500cm
3
/min
Nominal volume
Minimum volume
1
)
(at maximum
stroke)
(at compulsory stroke, design value only under
difficult conditions)
Volume per cycle
and outlet
Volume per cycle
and outlet
Number of
outlets
Description of
the sections
[cm
3
]
[cm
3
]
0.05
0.04
2
05T
0.10
0.08
2
1T
0.20
0.14
2
2T
0.30
0.18
2
3T
0.10
0.08
1
05S
0.20
0.16
1
1S
0.40
0.28
1
2S
0.60
0.36
1
3S
1) See explanation in Chapter 3.3, Information on volume data.
Progressive metering device VPK, basic design, Table 7
VPK Basic design with terminal for equipotential bonding
Type
hydraulically controlled
Mounting position
Any
Ambient temperature range
-25 to + 90 °C
- with cycle indicator
-20 to + 70 °C
Metering device sections
See Table 1
Used outlets, internal connection
3 to 20
Used outlets, external connection
1 to 19
Inlet and outlet threads
VPKM (metric thread)
M10x1
VPKG (inch thread)
G1/8
Material
Inlet plate, separator plate and end plate
Steel, tinned/nitrile-butadi-
ene rubber
Sections (piston plates)
Steel, galvanized
Hydraulic
Operating pressure max.:
Oil 200 bar, grease 300 bar
Volume per outlet and cycle
See Table 9
Lubricant
Mineral oils, greases based on mineral oil,
environmentally friendly and synthetic oils
and greases
Operating viscosity
> 12 mm
2
/s
Worked penetration
≥ 265 x 0.1 mm (up to NLGI Grade 2)
Содержание LINCOLN VP Series
Страница 113: ...16 Appendix 16 EN 113 951 180 083 EN Version 02 16 Appendix 16 1 Declaration of Conformity proximity switch...
Страница 115: ...115 951 180 083 EN Version 02 Notes...
Страница 117: ......