MAINTENANCE INSTRUCTIONS
An annual inspection of the heater by qualified service personnel is recommended to check for
proper operation and to look for damage or degradation of any component. Any damaged or
deteriorated parts should be replaced before the unit is put back into service.
1. Turn off all electrical power before inspection and servicing.
2. Check the heat chamber for cracks and blockage.
3. Check and clean burners and the igniter from dirt, rust and blockage by insects.
4. Check venting system for blockage by debris, including debris from animals and insects.
5. Check the piping for leaks.
6. Check and clean fan blades and fan guards from dirt, dust and blockage.
39
Содержание Sleeptight 800
Страница 16: ...SYSTEM COMPONENTS LP Gas Hose Assembly Fresh Air Fan Module 2 way LP Tank Manifold 15 Interconnect Cable ...
Страница 17: ...16 GAS TRAIN COMPONENTS ITEM DESCRIPTION 3 GAS CONTROL VALVE 4 CSST TUBE 5 IGNITER CABLE 6 IGNITER 3 4 5 6 ...
Страница 36: ...35 FRESH AIR MODULE WIRING DIAGRAM ...
Страница 41: ...Sisu Commercial Products LLC 5801 E 41st St Suite 1005 Tulsa OK 74135 www sisu ee com ...