AIR QUALITY WARNING
•
Do not use this heater for heating human living quarters.
•
Use of direct-fired heaters in the construction environment can result in exposure to levels of CO, CO2, and NO2
considered to be hazardous to health and potentially life threatening.
•
Do not use in unventilated areas
•
Know the signs of CO and CO2 poisoning
•
Headaches, stinging eyes
• Dizziness,
disorientation
• Diff iculty breathing, feels of being suff ocated
•
Proper ventilation air exchange (OSHA 29 CFR 1926.57) to support combustion and maintain
•
acceptable air quality shall be provided in accordance with OSHA 29 CFR Part 1926.154, ANSI
•
A10.10 Safety Requirements for Temporary and Portable Space Heating Devices and
•
Equipment used in the Construction Industry or the Natural Gas and Propane Installation
•
Codes CSA B149.1
•
Periodically monitor levels of CO, CO2 and NO2 existing at the construction site – at the minimum at the start
of the shift and aft er 4 hours.
•
Provide ventilation air exchange, either natural or mechanical, as required to maintain acceptable indoor air
quality.
WARNING
Air Quality Hazard
•
Ensure that the flow of combustion and ventilation air exchange cannot become obstructed.
•
As the building ‘tightens up’ during the construction phases ventilation may need to be
• increased.
HIGH ALTITUDE USE
Installation or use of this appliance at altitudes above 2000 ft (610 m) shall be in accordance with
local codes, or in the absence of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA
54, or National Standard of Canada, Natural Gas and Propane Installation Code, CSA B149.1.
USA 8-Hr Time weighted average
Canada 8-hr time weighted average
(OSHA 29 CFR 1926.55 App A)
WorkSafe BC OHS Guidelines Part 5.1
and Ontario Workplaces Reg 833
CO 50 ppm
CO 25 ppm
CO
2
5000 ppm
CO
2
5000 ppm
NO
2
NO
2
3 ppm (Reg 833)
USA-Ceiling Limit
(Short Term Exposure Limit=15 minutes)
Canada STEL (15 minutes Reg 833/1 hour WSBC) WorkSafe BC OSH
Guidelines Part 5.1 and Ontario Worksplaces Reg 883
CO
CO 100 ppm
CO
2
CO
2
15000 ppm (WSBC)
30000 ppm (Reg 833)
NO
2
5 ppm
NO
2
1.0 ppm (WorkSafeBC)
5.0 ppm (Reg 833)
5
Содержание Sleeptight 800
Страница 16: ...SYSTEM COMPONENTS LP Gas Hose Assembly Fresh Air Fan Module 2 way LP Tank Manifold 15 Interconnect Cable ...
Страница 17: ...16 GAS TRAIN COMPONENTS ITEM DESCRIPTION 3 GAS CONTROL VALVE 4 CSST TUBE 5 IGNITER CABLE 6 IGNITER 3 4 5 6 ...
Страница 36: ...35 FRESH AIR MODULE WIRING DIAGRAM ...
Страница 41: ...Sisu Commercial Products LLC 5801 E 41st St Suite 1005 Tulsa OK 74135 www sisu ee com ...