The Sleeptight 800 is designed for indoor use only. It is intended for use in providing portable,
temporary heat to buildings under construction, alteration or repair. Adequate ventilation must
be provided while heater is operating. Combustible solids, such as building materials, paper or
cardboard must be kept at the minimum distance from the heater as shown in the table below.
Never use this heater in spaces which do or may contain volatile or airborne combustibles,
or products such as gasoline, solvents, paint thinner, dust particles or unknown chemicals.
Adequate building relief must be provided so as to not over pressurize the building when this
heater is operating at its rated capacity.
OMNI Test Laboratories certified to ANSI Z83.7-2017•CSA 2.14-2.017 Gas-Fired Construction Heater
Gases:
Propane
Capacity:
80,000 Btu/Hr maximum
Blower:
1600
CFM
Electrical:
115V, 60Hz, 1Ph, 4.7 Amps starting, 3.2 Amps continuous
Min Amb Temp:
-20 Degrees F
Max Amb Temp:
140 Degrees F
Min Gas Supply Press:
11 in. W.C.
Max Gas Supply Press:
13.5 in. W.C.
Burner Manifold Press:
8 in. W.C.
Manufacturer:
L.B. White Co., LLC. Onalaska, WI
SYSTEM DESCRIPTION
SPECIFICATIONS
6
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS
Top
24 inches
Outlet side
24 inches
Inlet Side
24 inches
Front/Back
24 inches
Содержание Sleeptight 800
Страница 16: ...SYSTEM COMPONENTS LP Gas Hose Assembly Fresh Air Fan Module 2 way LP Tank Manifold 15 Interconnect Cable ...
Страница 17: ...16 GAS TRAIN COMPONENTS ITEM DESCRIPTION 3 GAS CONTROL VALVE 4 CSST TUBE 5 IGNITER CABLE 6 IGNITER 3 4 5 6 ...
Страница 36: ...35 FRESH AIR MODULE WIRING DIAGRAM ...
Страница 41: ...Sisu Commercial Products LLC 5801 E 41st St Suite 1005 Tulsa OK 74135 www sisu ee com ...