5. Check for electrical continuity across the switch terminals to make sure the contacts have closed. Install the
red cap; reinstall back into the heater and connect the wires to the terminals.
Reset Button
Sensing Surface
Terminal
Flame
Mounting Leg
GAS CONTROL VALVE
1. Disconnect the heater from it’s power source.
2. Remove the gas supply hose and elbow/hose adapter from the heater’s gas inlet.
3. Open the door to gain access to the components.
4. Remove the brown and green wires attached at the top of the gas valve.
5. Remove the brass compression nut securing the stainless steel flexible gas line to the outlet of the gas valve.
6. Remove the 2 screws securing the left gas valve bracket.
7. Remove the gas valve from the heater.
31