b. Installations in Canada:
-- CAN1-B149.1 or CAN1-B149.2 Installation Codes
-- CSA C22.1 Part 1 Standard Canadian Electrical Code.
-- CSA C22.2 No.3, Electrical Features of Fuel Burning Equipment.
3. We cannot anticipate every use which maybe made of our heaters. Other standards govern the use of fuel
gases and heat producing products in specific applications. Your local authority can advise you about
these. Check with the local fire safety authority if you have questions about applications.
4. Do not wash the heater. Use only compressed air, a soft brush or dry cloth to clean the interior of the
heater and it’s components.
5. For safety, this heater is equipped with a manual reset high limit switch, and an air pressure switch. Never
operate the heater with any safety device that has been bypassed. Do not operate this heater unless all of
these features are fully functioning.
6. Do not direct the heater toward any propane gas supply container or gas hose within 20 ft . (6m) of the
heaters hot air discharge.
7. Do not block air intakes or discharge outets of the heater. Doing so may cause improper combustion or
damage to heater components leading to property damage.
8. The hose assembly shall be visually inspected on a daily basis aft er heater relocation and when the heater
is in use. If it is evident there is excessive abrasion or wear, or if the hose is cut, it must be replaced prior
to the heater being put into operation. The hose assembly shall be protected from building materials, and
contact with hot surfaces both during use and while in storage. The replacement hose assembly shall be
that specified by the manufacturer. See parts list.
9. Check for gas leaks and proper function upon heater installation, when relocating, and aft er servicing.
Refer to leak check instructions within the installation section of this manual.
10. This heater should be inspected for proper operation by a qualified service person before each use and
at least annually.
11. Always turn off the gas supply to the heater if the heater is not going to be used in the heating of the work
space.
12. If gas flow is interrupted and flame goes out, do not relight the heater until you are sure that all gas that
may have accummulated has cleared away. In any event, do not relight the heater for at least 5 minutes.
11
Содержание Sleeptight 800
Страница 16: ...SYSTEM COMPONENTS LP Gas Hose Assembly Fresh Air Fan Module 2 way LP Tank Manifold 15 Interconnect Cable ...
Страница 17: ...16 GAS TRAIN COMPONENTS ITEM DESCRIPTION 3 GAS CONTROL VALVE 4 CSST TUBE 5 IGNITER CABLE 6 IGNITER 3 4 5 6 ...
Страница 36: ...35 FRESH AIR MODULE WIRING DIAGRAM ...
Страница 41: ...Sisu Commercial Products LLC 5801 E 41st St Suite 1005 Tulsa OK 74135 www sisu ee com ...