IGNITER AND FLAME SENSOR ASSEMBLY
The igniter is a local sense design, meaning it also serves to sense burner flame. For igniter/flame sensor
location see Figure below.
1. Disconnect the high voltage cable from the igniter assembly.
2. Remove the 2 screws securing the igniter assembly to either the burner or the heat chamber
• The igniter and ground rod should be cleaned to maintain proper ignition.
-- Use steel wool or emery cloth.
-- Rub briskly to remove buildup of dust, dirt, and oxide.
• Check the igniter’s ceramic base for cracks.
-- Replace the igniter if cracks are found.
Igniter
Igniter Cable
0.125 in (3.18 mm)
to 0.188 (4.78 mm)
GAP