• If you have not been properly trained in repair and service of propane gas fueled heaters, then do not
attempt to light the heater, perform service or repairs, or make any adjustments to the propane gas system.
• Even if you are not properly trained in the service and repair of force air heaters, ALWAYS be consciously
aware of the odor of propane gas.
• A periodic “sniff test” around the heater or at the heater’s joints; i.e. hose, connections, etc., is a good safety
practice under any conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER
IMMEDIATELY. DO NOT WAIT!
1. Do not attempt to install, repair, or service this heater or the gas supply line unless you have continuing
expert training and knowledge of gas heaters.
QUALIFICATIONS FOR SERVICING AND OPERATION:
a. To be a qualified gas heater service person, you must have been trained in gas-fired heater servicing,
repair and also have suff icient experience to allow you to troubleshoot, replace defective parts, and test
heaters in order to get them into a continuing safe and normal operation condition. You must completely
familiarize yourself with each model heater by reading and complying with the safety instructions, labels,
owner’s manual, etc. that are provided with each heater.
b. To be a qualified gas installation person, you must have suff icient training and experience to handle
all aspects of installing, repairing, and altering gas lines, including selecting and installing the proper
equipment, and selecting proper pipe size to be used. This must be done in accordance with all local, state
and national codes as well as the manufacturer’s requirements.
c. In the Commonwealth of Massachusettes, this product must be installed by a gas fitter licensed in the
Commonwealth of Massachusettes.
2. All installations or applications of this heater shall meet the requirements of local, state and national L.P.
gas and natural gas, electrical and safety codes. Your gas supplier, local licensed electrician, local fire
department and government agencies can help you determine these requirements. In the absence of local
codes, comply with the following:
a. Installations in the U.S.A.:
-- NFPA 102, standard for assembly seating, tents and membrane structures
-- ANSI/NFPA 58, latest edition, Standard for Storage and Handling of Liquefied Petroleum Gas and/or
-- ANSI Z223.1/NFPA 54, National Fuel Gas Code -- ANSI/NFPA 70, National Electrical Code.
10
Содержание Sleeptight 800
Страница 16: ...SYSTEM COMPONENTS LP Gas Hose Assembly Fresh Air Fan Module 2 way LP Tank Manifold 15 Interconnect Cable ...
Страница 17: ...16 GAS TRAIN COMPONENTS ITEM DESCRIPTION 3 GAS CONTROL VALVE 4 CSST TUBE 5 IGNITER CABLE 6 IGNITER 3 4 5 6 ...
Страница 36: ...35 FRESH AIR MODULE WIRING DIAGRAM ...
Страница 41: ...Sisu Commercial Products LLC 5801 E 41st St Suite 1005 Tulsa OK 74135 www sisu ee com ...