B. Gauge Installation
1. Locate the inlet and outlet pressure taps, see Figure below. Loosen the pressure tap screw using a 3/32 Allen
key.
2. Securely connect a pressure gauge to each pressure tap.
3. Open the fuel supply valves to the heater and reconnect the heater electrical supply.
4. Start the heater
C. Reading Pressures
1. With the heater operating, the pressure gauges should read the pressures specified on the dataplate .
2. If the readings at the inlet and outlet pressure gauges agree with that specified on the dataplate, then no
further checking or adjustment is required. Proceed to section D.
3. If the inlet pressure does not agree with that specified on the dataplate, then the regulator controlling gas
pressure to the heater requires adjustment.
4. If the inlet pressure is correct and the burner manifold pressure does not agree with that specifed on the
dataplate, then the gas control valve’s internal pressure regulator requires adjustment. See previous figure
for regulator location.
5. Remove the regulator adjustment cap screw and turn the internal screw clockwise to increase or counter
clockwise to decrease to the desired pressure.
6. Install the regulator cap back onto the gas valve when completed. Tighten securely.
Outlet
Pressure
Tap
Regulator
Adjustment Cap
Inlet Pressure Tap
34
Содержание Sleeptight 800
Страница 16: ...SYSTEM COMPONENTS LP Gas Hose Assembly Fresh Air Fan Module 2 way LP Tank Manifold 15 Interconnect Cable ...
Страница 17: ...16 GAS TRAIN COMPONENTS ITEM DESCRIPTION 3 GAS CONTROL VALVE 4 CSST TUBE 5 IGNITER CABLE 6 IGNITER 3 4 5 6 ...
Страница 36: ...35 FRESH AIR MODULE WIRING DIAGRAM ...
Страница 41: ...Sisu Commercial Products LLC 5801 E 41st St Suite 1005 Tulsa OK 74135 www sisu ee com ...