NOTICE
The bolt position is not monitored in the .AP2 AntiPanic Cylin
der.
Select 'Off' for the number of turns for the .AP2 Cylinder
Select 'Off' for door securely locked position for the .AP2 Cylinder
– Logging of access list: this is where you enter whether 'Door open'
and dead bolt events are to be saved to the access list
– Transmission in the network: this is where you enter whether
'Door open' and dead bolt events are to be saved in LSM via the
WaveNet network
– Logging/forwarding of alarms in the network: this is where you
enter whether alarms are to be saved in LSM via the WaveNet
network. Forwarding must also be configured for the LN.I via
'Network' » 'Administer WaveNet.' The alarm alerts transmitted
are:
– Door open too long
– Tampering attempt
– Door is open even though it registers as locked or securely
locked
NOTICE
If events are not logged in the access list, it will not be possible
to establish at a later point in time who has used a particular
door.
Status
Illustration 10:
'Status' tab
The 'Status' tab shows the last status read in the locking device
– Battery status: indicates whether the batteries need to be replaced
– Emergency release: the software uses an emergency release to
engage the cylinder
– Deactivated: the cylinder is deactivated. The cylinder will not
engage even if an authorised transponder is used.
– Engaged: the cylinder is engaged.
Manual
Door Monitoring Cylinder
20 / 72