END USER GUIDE
RCI DE8310 V1.6
DELAYED EGRESS V1.6 ELECTROMAGNETIC LOCKS
© 2020 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: [email protected]
ZLDE8310EUG-V16
PCN18041
R01-20GR
PLEASE GIVE TO END USER
Nuisance Period:
Some installations have a short nuisance period set to accommodate accidental triggering.
If the pressure on the door is withdrawn during the nuisance delay period, the system returns to normal conditions on its own.
System Status
Light Panel *
Local Buzzer
(if connected)
Local Alarm Relay Output
(if connected)
Remote Alarm Relay Output
(if connected)
Nuisance Delay
Period
Blinking Red
fast
Pulsing Sound
ON
ON
System Status
Light Panel *
Local Buzzer
(if connected)
Local Alarm Relay Output
(if connected)
Remote Alarm Relay Output
(if connected)
Release Delay
Period
Blinking Red -
slowly
Steady Sound
ON
OFF
Lock Release
Blinking Red & Green -
alternately
Steady Sound
until reset
ON
OFF
Normal Conditions:
In normal conditions with the door closed and locked.
System Status
Light Panel *
Local Buzzer
(if connected)
Local Alarm Relay Output
(if connected)
Remote Alarm Relay Output
(if connected)
Door Locked
Green
OFF
OFF
ON
System Status
Light Panel *
Local Buzzer
(if connected)
Local Alarm Relay Output
(if connected)
Remote Alarm Relay Output
(if connected)
Exit Switch to Open
(Authorized Exit)
Red
OFF
OFF
OFF
To Exit:
If a Nuisance Delay is enabled, maintained pressure past its time will start the irreversible release delay.
If a Nuisance Delay is not enabled, slight pressure will start the irreversible release delay.
The release delay time is posted on the door.
Pressure is no longer required on the door.
The lock will release when the delay period ends.
The system now needs to be manually RESET using the keyswitch in order for the buzzer to stop.
To By-Pass the Delay Period and Exit:
Manually OVERRIDE using the keyswitch to release the door.
When the door closes, the system returns to normal conditions.
Door Forced Open:
If this happens before the release delay period has lapsed, the buzzer indicators can only be turned off by switch-
ing the system power off.
System Status
Light Panel *
Local Buzzer
(if connected)
Local Alarm Relay Output
(if connected)
Remote Alarm Relay Output
(if connected)
Forced Open
Blinking Red - Fast
Pulsing Sound
ON
OFF