The DoorMonitoring Cylinder [DM] logs access events (access lists)
and monitors door status and changes to door status (open, closed,
locked, securely locked, manipulation attempt and forced entry).
The following door statuses are logged:
– Door – open or closed
– Cam rotated once/twice (maximum four times) door unlocked /
locked / securely locked
– Alarm
These door statuses can be transmitted to LSM via the WaveNet
network, where they can be displayed, so that the user can see the
transmitted status easily.
LSM allows you to define events which trigger a definable, time
dependent response, such as a popup window with a warning or an
email, when the status of a locking device changes.
All changes are logged in the access list, including the transponder
ID, date and time, which the locking system operator or a security
officer can then upload and evaluate if necessary.
1.3 Specifications
Standard design
The DM Cylinder is supplied in the following standard configuration:
– .DM DoorMonitoring
– .G2 available as G2 only
– .ZK access control, time zone management and events logging
The following accessories must be ordered with the standard
configuration:
– Z4.DM.dd.SCREW.n Fastening Screw
NOTICE
You must indicate the backset when ordering the fastening
screw
The fastening screw is manufactured to match the backset and is a
few millimetres longer
Information is only correctly transferred to the cylinder if the fastening
screw is the right length.
dd represents the lock's backset. Standard fastening screws are
supplied for backsets between 25 and 110 mm at increments of
5 mm. Greater lengths are possible at increments of 5 mm.
Options
The following options are available for the DM Cylinder:
– .FD freely rotating
– .AP2 antipanic cylinder (no monitoring in the bolt position)
Manual