Manual
Door Monitoring Cylinder
63 / 72
SimonsVoss
4 | Maintenance
NOTICE
A door can only be opened with a battery replacement transpon
der once in freeze mode.
Normal transponders can no longer open a door
a) Replace the batteries immediately after the first warning level
starts
Battery replacement
ü
You have a battery replacement key
ü
You have a battery replacement transponder
ü
You have new battery replacement batteries
ü
You have an authorised transponder
1.
If the cylinder is in freeze mode, activate the battery replacement
transponder
ð
The cylinder can now be opened with an authorised
transponder
2.
Activate the authorised transponder
3.
Replace the batteries
4.
Activate the battery replacement transponder
ð
Freeze mode is permanently eliminated. The cylinder can be
operated as normal
Replacing batteries
1.
Place the installation/battery key on the inside thumbturn in
such a way that the two teeth lock into the openings in the
locking disc; if necessary, turn the thumbturn until both teeth
engage into the locking disc. Important: The tool must be placed
flat on the inside front surface of the recessed grip ring to ensure
that the installation tool can engage into the locking disc. . Use
clean gloves free of fat or grease to handle new batteries.
2.
Hold the inside thumbturn firmly and carefully turn the
installation/battery key about 30° in a clockwise direction until
you hear a click.
3.
Remove installation/battery key from the thumbturn
4.
Push recessed grip ring backwards towards the door, so that it
comes away from the thumbturn
5.
Hold recessed grip ring firmly and turn thumbturn about 10° in
an anticlockwise direction and remove
6.
Carefully remove both batteries from the holder
7.
Insert the new batteries into the holder at the same time with the
positive poles next to each other; change the batteries as quickly
as possible
Содержание 3061 DM