3 Daytoday operation
3.1 Displays
You can display the key information about your locking system
directly in the locking plan. The DM Cylinder's door statuses can be
shown directly on the locking plan
– This view is only useful if the DM Cylinder is connected online
– If a wireless node (LockNode) fails, the system does not detect
the fault until the cylinder is addressed by the LSM (reading,
reprogramming). That is why it is sensible to check the status of
the WaveNet network
– The cylinders transmit all status changes to LSM (LSM Basic) or
the CommNode server (Business / Professional) in real time. If
LSM is closed, the status displayed at that moment is saved
– If a door status changes while LSM is closed (Basic) or the
CommNode server has been paused (Business / Professional),
the system does not record this change. The correct status is not
displayed until a change has been made to the status at the door
Illustration 14:
Additional columns in the locking plan
1.
Click on 'Options' > 'Additional columns' > 'Locking devices/
doors' in the menu row
Manual
Door Monitoring Cylinder
56 / 72
SimonsVoss
3 | Daytoday operation