4 | Maintenance
4 Maintenance
4.1 Audible signals
Signal type
Meaning
Action required
2 short audible signals
before engaging and a
short tone after
disengaging
Normal activation
No
1 short audible signal:
cylinder does not
engage.
Attempted entry with a
transponder listed in
the locking system,
but: booked outside
the time zone: no
authorisation, cylinder
is deactivated
Check authorisations.
Read locking device,
check status. Check
time zone plan
8 short audible signals
before engaging:
Battery Warning Level
1
Batteries are low
Replace batteries in
the cylinder
8 short audible signals
30 seconds long with
one second pause
each time before
engaging: Battery
Warning Level 2
Batteries are almost
completely empty
Replace batteries in
the cylinder
immediately.
6 audible signals (long
– pause – short):
Freeze mode
Battery empty.
Cylinder can no longer
be opened using an
authorised
transponder.
Replace batteries and
reset with a battery
replacement
transponder.
8 short audible signals
after thumbturn
disengages
Transponder battery is
low
Have transponder
battery replaced
Table 3:
Cylinder audible signals
4.2 Batteries
Battery life
The battery life depends on the DM Cylinder configuration settings
and the use behaviour. The following affect the battery life:
– The fastening screw sampling interval
– Number of activations
– Reading the access list
– Changes to programming