background image

Sargent and Greenleaf®

USB Audit Lock 2.0 Operating Instructions

3006 Pivot Bolt & 3007 Direct Drive   

The Sargent & Greenleaf Audit Lock is designed to provide a high 

level of security combined with flexible features that allow multiple 

levels of control over normal operations. Follow these instructions 

carefully to get the best possible use from your lock.

Document: 630-888

 Revised: 5.23.16

Содержание 3007 Direct Drive

Страница 1: ... Drive The Sargent Greenleaf Audit Lock is designed to provide a high level of security combined with flexible features that allow multiple levels of control over normal operations Follow these instructions carefully to get the best possible use from your lock Document 630 888 Revised 5 23 16 ...

Страница 2: ...approach works best for you All codes end with This signals the lock that you have finished entering all digits of the code This is a battery operated product 9 Volt Alkaline Duracell Batteries recommended Cables longer than 3 meters should not be connected to the keypad USB port A small musical note is used within these instructions to indicate the beep that the lock makes USB and AuditTrail was ...

Страница 3: ...ing a PIN Code 8 3 8 Command 42 Identify LockType 8 3 9 Command 43 Identify Lock Mechanics 8 3 10 Command 44 Identify Operating Mode 8 3 11 Command 46 Setting Up theTime Delay Override Options 8 9 3 12 Command 47 Setting up theTime Delay 9 3 13 Command 48 Setting Up the OpeningWindow 9 3 14 Command 55 Enable Disable the Lock manager employee mode 9 3 15 Command 56 Enable Disable User Disable Featu...

Страница 4: ...ering a PIN position and PIN Code which makes up an 8 digit User code followed by the key To open the lock use the factory setting for PIN position 10 with PIN Code 10101010 Enter 10101010 and the lock should open If lock does not open and beep patterns were heard after pressing the key reference Section 2 3 Beep Patterns to identify condition We recommend that Users change their PIN Codes immedia...

Страница 5: ...nispressed Beep2 Lowerpitchthanbeep1 Action Condition Tone KeypadLED LED Color Duration Normalcondition Eachkeystroke 1 beep1 1cycle Lowbattery 2 beep1 Red 5cycles Batterytoolow 20 beep1 Red 1cycle Tamperindication 3 beep1 3 beep1 3 beep1 Red 2cycles Starttimedelay 3 quickbeep1 Red 1cycle Timedelaycountdown 1 beep1 Red Every10seconds Timedelayexpired 10 quickbeep1 Green 1cycle Openingwindow countd...

Страница 6: ...carefully remove the keypad housing by lifting up the bottom edge of the keypad closest to the S G logo Move the spring clips under each battery to release the battery Insert the new batteries into the propercompartmentandmovethespringclipsbackintoplace Pressthekeypad housingfirmlybackontothebase 2 10 USB Flash Drive AconnectorportforarecommendedUSBflashdriveisprovidedonthefrontof thekeypad Thisco...

Страница 7: ...of 0 2 0 2 0 2 0 2 has been changed to 2 1 2 1 2 1 2 1 Example Step 1 Enter 2 2 Step 2 1 0 1 0 1 0 1 0 Step 3 2 0 1 5 2 0 1 5 Step 4 2 0 1 5 2 0 1 5 With the lower left example the default PIN code of 1 0 1 0 1 0 1 0 has been changed to 2 0 1 5 2 0 1 5 3 5 Command 28 Audit Download The S G Audit Lock 2 0 AuditTrail can store as many as 1 000 events that include the time date Some examples of event...

Страница 8: ...beep one low beep to begin the sequence The next set of beeps will indicate the type of lock mechanics that are being used 1 beep PIVOT BOLT 2 beeps DIRECT DRIVE 3 beeps MOTOR DRIVE 4 beeps MOTOR GEAR 3 10 Command 44 Identify Operating Mode Usethiscodetoverifythatthefirmwareversionthathasbeenloadedintothelock Step 1 Enter 4 4 Step 2 Listen for the beeps to determine the operating mode The lock wil...

Страница 9: ...ngWindow If the time delay has already been set enter a User Code to start the time delay When the time delay expires the lock emits 10 rapid beeps and the opening window has begun immediately proceed to set the opening window minutes by performing the following steps Step 1 Enter 4 8 Step 2 Enter 8 digit Programmer PIN Code 00 Step 3 Enter Opening window minutes 1 99 Step 4 Enter Opening window m...

Страница 10: ...ode has been lost or needs to be reset Step 1 Enter 6 7 Step 2 Enter 8 digit Programmer PIN Code 00 Step 3 Enter New 8 digit MRC value Step 4 Enter New 8 digit MRC value 3 17 Command 67 Setting Using MRC Function cont Example To add an MRC with a value of 98765432 Step 1 Enter 6 7 Step 2 Enter 0 0 1 2 3 4 5 6 PC 8 digit Code Step 3 Enter 9 8 7 6 5 4 3 2 new MRC value Step 4 Enter 9 8 7 6 5 4 3 2 n...

Страница 11: ...et Pleasenotethatthelockwillremaininthisfunctionuntilthe key ispressedorthereare10secondsbetweenkeypresses 3 21 Command 79 Identify FirmwareVersion Use this code to verify that the firmware version that has been loaded into the lock Step 1 Enter 7 9 Step 2 Listen for the beeps to determine the firmware version The lock will emit one low beep one high beep one low beep to begin the sequence The nex...

Страница 12: ...n designed with built in encryption or other security features will not work as expected with the USB Audit Lock 2 0 These drives typically require additional input from the end user before they can be used and this is not available through the keypad S G Confidential The information contained in this document is proprietary to Sargent Greenleaf Inc Publication or duplication of this copyrighted d...

Отзывы: