3.11 — Command 46: Setting Up the Time Delay
Override Options (cont.)
Example…
To enable TDO type 2:
Step 1
Enter: 4 6 *
Step 2
Enter: 0 0 1 2 3 4 5 6 # (PC 8-digit Code)
Step 3
Enter: 2 # (TDO type – 1 or 2)
Step 4
Enter: 2
# (TDO type – 1 or 2)
The TDO TYPE 2 function has now been enabled. The code in position 29 can
now be used to open the lock without waiting for the time delay countdown.
3.12 — Command 47: Setting up the Time Delay
The USB Audit Lock 2.0 can be programmed with a time delay feature. Time
delay applies only to those users who can open the lock. The time delay can be
set from 0 to 99 minutes. If the lock is in the time delay period, the LED red light
on the keypad flashes and a single beep sounds every 10 seconds.
When the time delay expires, the lock emits 10 rapid beeps to indicate that
the opening window has started and the lock can now be opened. During this
opening window the lock beeps and the LED flashes twice every 10 seconds.
The opening window factory default is set for 2 minutes, and the opening
window can be set from 1 to 99 minutes.
To open the lock when a time delay has been programmed, a User must
enter their User Code to start the time delay period, wait the length of the time
delay period and then enter a valid User Code during the opening window.
If the lock is not opened during the open window period, it automatically resets
and the process must be repeated.
The USB Audit Lock 2.0 comes from the factory with no time delay set.
Set time delay duration
If the time delay has already been set, enter a User Code to start the time delay.
When the time delay expires (the lock emits 10 rapid beeps) and the opening
window has begun, immediately proceed to change the time delay by
performing the following steps:
Step 1 Enter: 4 7 *
Step 2 Enter: 8-digit Programmer PIN Code (00) #
Step3 Enter: Time delay minutes (0-99) #
Step 4 Enter: Time delay minutes again (0-99) #
Example...
To set the time delay to 10 minutes:
Step 1
Enter: 4 7*
Step 2
Enter: 0 0 1 2 3 4 5 6 #
Step 3
Enter: 1 0 # (Number of Minutes Time Delay)
Step 4
Enter: 1 0 #
(Number of Minutes Time Delay)
3.12 — Command 47: Setting up the Time Delay (cont.)
To eliminate the time delay period, simply enter zero (0) for the time
delay minutes.
3.13 — Command 48: Setting Up the Opening Window
If the time delay has already been set, enter a User Code to start the time delay.
When the time delay expires (the lock emits 10 rapid beeps) and the opening
window has begun, immediately proceed to set the opening window minutes
by performing the following steps:
Step 1
Enter: 4 8*
Step 2
Enter: 8-digit Programmer PIN Code (00) #
Step 3
Enter: Opening window minutes (1-99) #
Step 4
Enter: Opening window minutes again
(1-99)
#
Example...
To set the opening window to 5 minutes:
Step 1
Enter: 4 8 *
Step 2
Enter: 0 0 1 2 3 4 5 6
# (Programmer PIN Code)
Step 3
Enter: 5
# (Number of Minutes For Opening Window)
Step 4
Enter: 5
# (Number of Minutes For Opening Window)
If time delay has not been previously set, the setting of the opening window
may begin immediately upon input of the correct code sequence.
3.14 — Command 55: Enable / Disable the Lock
(manager / employee mode)
The USB Audit Lock 2.0 can be programmed to work in manager / employee
mode. In this mode, Managers and Supervisors enable the lock and Users open
the lock (only when enabled). Users can also be setup to disable the lock using
this command (using the 56* command). Please note that this function is only
available in manager / employee mode.
Enable / Disable the lock
When the lock is in manager / employee mode, the ability for Users to open the
lock can be toggled by performing the following steps. If the lock is disabled,
this function will enable the lock. If the lock is disabled, this function will
enable the lock.
Step 1
Enter: 5 5 *
Step 2
Enter: 8-digit Manager or Supervisor PIN code
(01 - 09) #
NOTE: Four high beeps indicate the lock is now enabled and 2 low beeps
indicate the lock is now disabled.
Step 1
Enter: 5 5 *
Step 2
Enter: 0 2 0 2 0 2 0 2 #
3.15 — Command 56: Enable/Disable User Disable Feature
(manager / employee mode)
When the lock is in manager / employee mode, the lock can be setup to allow
users to disable the lock. By default, only Managers and Supervisors have the
ability to disable the lock. This function will also allow the Users to disable the
lock (but the Users will not be able to enable the lock).
If the time delay has already been set, changes to the opening window and
time delay duration can only be made during the opening window.
IMPORTANT:
Do not set the time delay until you have
finished all other programming functions or you will have to
wait through the time delay before making any other
programming changes.
9