![Silicon Laboratories Si475X Series Скачать руководство пользователя страница 260](http://html1.mh-extra.com/html/silicon-laboratories/si475x-series/si475x-series_programming-manual_1272036260.webp)
A N 5 4 3
260
Rev. 0.9
Property 0x220E AM_CHBW_RQ_NARROWING_TIME
The AM_CHBW_RQ_NARROWING_TIME property sets the RSSI based channel filter bandwidth narrowing
time. The CTS bit (and optional interrupt) is set when it is safe to send the next command. This property may only
be set or read in powerup mode.
Si475x-A40 and earlier is not available.
Si475x/5xC-A55, Default: 16
Property 0x2300 AM_DEMOD_MODE
The AM_DEMOD_MODE property selects the demodulation technique. To force to envelope demodulation, set this
property to 0x0100. The CTS bit (and optional interrupt) is set when it is safe to send the next command. This
property may only be set or read in powerup mode.
Si475x-A40 and earlier, Default: 0x0001
Si475x/5xC-A55, Default: 0x0100
AM_CHBW_RQ_NARROWING_TIME
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
NARROWING_TIME[15:0]
0x0010
Bit
Name
Function
15:0
NARROWING_TIME[15:0]
Sets the RSSI based channel filter bandwidth narrowing time.
Default is 16 ms.
AM_DEMOD_MODE
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0x00
IQSNR
FIXED_MODE
0x00
MODE[2:0]
0x00
0
1
0x00
0x0
Bit
Name
Function
15:10
Reserved
Always write to
0.
9
IQSNR
(Available in Si475x-A40 and A55 only)
When set, enables the I/Q SNR metric, which is more robust when AM car-
rier varied greatly (as with AM-SS).
0 = Normal SNR metric
1 = Enable AM-SS resistant SNR metric. This should only be used with
envelope demodulation.
8
FIXED_MODE
0 = The demodulation technique is not fixed.
1 = The demodulation technique is fixed and will not automatically switch.