![Silicon Laboratories Si475X Series Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/silicon-laboratories/si475x-series/si475x-series_programming-manual_1272036021.webp)
AN543
Rev. 0.9
21
Table 9. Status Response for the AM Receiver
Bit
7
6
5
4
3
2
1
0
STATUS
CTS
ERR
XX
RSQINT
X
ACFINT
STCINT
Bit
Name
Function
7
CTS
Clear to Send.
0 = Wait before sending next command.
1 = Clear to send next command.
6
ERR
Error
0 = No error.
1 = Error.
5:4
Reserved
Values may vary.
3
RSQINT
Received Signal Quality Interrupt
0 = Received Signal Quality measurement has not been triggered.
1 = Received Signal Quality measurement has been triggered.
2
Reserved
Value may vary.
1
ACFINT
Automatically Controlled Features Interrupt.
0 = ACF measurement has not been triggered.
1 = ACF measurement has been triggered.
0
STCINT
Seek/Tune Complete Interrupt.
0 = Tune complete has not been triggered. Do not send a new TUNE/SEEK
command.
1 = Tune complete has been triggered. It is safe to send a new TUNE/
SEEK command.