A N 5 4 3
104
Rev. 0.9
Property 0x1304 FM_ACF_HIBLEND_THRESHOLD
The FM_ACF_HIBLEND_THRESHOLD property sets the HIBLEND interrupt threshold in units of 100 Hz. When
the HIBLEND cutoff frequency falls below this threshold and the HIBLEND_INT interrupt is enabled through the
FM_ACF_INTERRUPT_SOURCE property, the HIBLEND_INT interrupt will be asserted. The CTS bit (and
optional interrupt) is set when it is safe to send the next command. This property may only be set or read in
powerup mode.
Default: 0
Units: 100 Hz
FM_ACF_HIBLEND_THRESHOLD
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0x00
HIBLEND_THRESH[7:0]
0x00
0x00
Bit
Name
Function
15:8
Reserved
Always write 0.
7:0
HIBLEND_THRESH[7:0]
HIBLEND interrupt threshold in units of 100 Hz, which triggers the
HIBLEND Interrupt when the HIBLEND cutoff frequency falls below this
threshold.
Default is 0.
Range is 0–200.